TECHNICAL SPECIFICATIONS - L140
The L140 De Bug microbial decontamination treatment unit eliminates existing microbial infestation and continues to prevent infestation from reoccurring simply by using the engine or recirculation system. If you have bugs in your diesel fuel, you can expect a notable improvement in power, reduction in fuel use and a longer filter life.
SPECIFICATIONS
APPLICATIONS
: For diesel fuel, marine diesel, light oils and gas oil Suitable for
most smaller vehicles such as 1-2 tonne trucks, vans, small to medium size
buses, gen sets, fishing vessels, fork lift vehicles and agricultural
equipment
ENGLINE RATINGS: To suit all diesel engines rated up to 100 hp
(74.5 kw) (as a guide only)
FUEL FLOW RATE: Recommended fuel flow rate of 140 LPH
FUEL FLOW DIRECTION: Left to right
SIZE: 60 mm (D) x 105 mm (H) x 84 mm (W)
PORT SIZE: 1/4 inch National Pipe Thread (NPT) or British Standard Pipe Thread
(BSPT)
MATERIALS: LM6, marine grade, anti corrosive, aluminium
alloy
INSTALLATION: Two 8 mm mounting holes in the backing flange. Brass fittings are recommended for the ports.
Model L140 Installation & Maintenance Guide - PDF
TECHNICAL SPECIFICATIONS - L500
The L500 De Bug microbial decontamination treatment unit eliminates
existing microbial infestation and continues to prevent infestation from
reoccurring simply by using the engine or recirculation system. If you have bugs
in your diesel fuel, you can expect a notable improvement in power, reduction in
fuel use and a longer filter life.
SPECIFICATIONS
APPLICATIONS: For diesel fuel, marine diesel, light oils and
gas oil Suitable for
fishing boats, generator sets, trucks, buses, tractors, 4 x 4 vehicles, bulk
tanks and fluid treatment at a flow rate of 500 LPH
ENGLINE RATINGS: To suit all diesel engines rated up to 100 - 300 hp
FUEL FLOW RATE: Recommended fuel flow rate of up to 500 LPH
FUEL FLOW DIRECTION: Left to right
WEIGHT: 1.5 kg
SIZE: 115 mm (D) x 160 mm (H) x 127 mm (W)
PORT SIZE: 1/2 inch National Pipe Thread (NPT)
OPERATING PRESSURE: Up to 50 psi
MATERIAL: Marine grade LM6 anti-corrosive aluminium alloy
INSTALLATION: Two 10 mm mounting holes in the backing flange. Brass fittings are
recommended for the ports
L500 Installation & Maintenance Guide - PDF
TECHNICAL SPECIFICATIONS - L1000
The L1000 De Bug microbial decontamination treatment unit eliminates
existing microbial infestation and continues to prevent infestation from
reoccurring simply by using the engine or recirculation system. If you have bugs
in your diesel fuel, you can expect a notable improvement in power, reduction in
fuel use and a longer filter life.
SPECIFICATIONS
APPLICATIONS : For diesel fuel, marine diesel, light oil and gas oil Fishing boats,
generator sets, large trucks, ferries, tug boats, crane, trains, small ship
engines and fluid treatment at a flow rate of 1000 LPH
ENGLINE RATINGS: To suit all diesel engines rated up to 100 - 600 hp
FUEL FLOW RATE: Recommended fuel flow rate of up to 1000 LPH
WEIGHT: 1.98 kg
SIZE: 110 mm (D) x 194 mm (H) x 114 mm (W)
PORT SIZE: 1/2 inch National Pipe Thread (NPT)
OPERATING PRESSURE: Up to 50 psi
MATERIAL: Marine grade LM6 anti corrosive aluminium alloy
MILITARY SPECIFICATION APPROVAL NATO Part Number - 2910-98-202-6290
Model L1000 Installation & Maintenance Guide - PDF
TECHNICAL SPECIFICATIONS - L2000
The L2000 De Bug microbial decontamination treatment unit eliminates
existing microbial infestation and continues to prevent infestation from
reoccurring simply by using the engine or recirculation system. If you have bugs
in your diesel fuel, you can expect a notable improvement in power, reduction in
fuel use and a longer filter life
SPECIFICATIONS
APPLICATIONS: For diesel fuel, marine diesel, light oil and gas oil Container
vessels, fishing boats, tug boats, ferries, small ship engines, generator sets,
crane, trains, and fluid treatment at a flow rate of 2000
LPH
ENGLINE RATINGS: 600 hp ¨C 1200 hp
FUEL FLOW RATE: Recommended up to 2000
LPH
WEIGHT: 7.5 kg
SIZE: 152 mm (D) x 360 mm (H) x 170 mm (W)
PORT SIZE: 1¡± Hydraulic Connectors
OPERATING PRESSURE: Up to 50 psi
MATERIAL: 316 Stainless Steel (powder coated)
Model L2000 Installation & Maintenance Guide - PDF
TECHNICAL SPECIFICATIONS - L5000
The L5000 De Bug microbial decontamination treatment unit eliminates
existing microbial infestation and continues to prevent infestation from
reoccurring simply by using the engine or recirculation system. If you have bugs
in your diesel fuel, you can expect a notable improvement in power, reduction in
fuel use and a longer filter life
SPECIFICATIONS
APPLICATIONS:
For diesel fuel, marine diesel, light oil, gas
oil, medium and heavy fuel oil Suitable for bulk carriers, oil tankers,
container vessels, tug boats, ferries, generator sets, crane, trains and fluid
treatment at a flow rate of 5000 LPH
ENGLINE RATINGS: 1,000 hp ¨C 8,000 hp
FUEL FLOW RATE:
Recommended up to 5000 LPH
FLOW
DIRECTION WITH UNIT MOUNTED: Inlet via central port and outlet by rear port.
WEIGHT: 21.5 kg
SIZE: 386 mm (D) x 333 mm (H) x 375 mm (W)
PORT SIZE: -24 SAE (1 1/2") Straight Thread O-Ring Boss
(ORB)
OPERATING PRESSURE:
Up to 50 psi
MATERIALS:
Marine grade LM24 anti-corrosive
Aluminum
alloy.
INSTALLATION: 4 x 16 mm mounting holes in the backing flange.
Model L5000 Installation & Maintenance Guide - PDF
TECHNICAL SPECIFICATIONS - KPU (L9600)
The KPU is a one pass free standing De Bug decontamination treatment
unit eliminates microbial infestation and continues to prevent infestation from
reoccurring as fuel tanks are filled from the dispenser. The
KPU can also be installed within the bowsers
casing.
SPECIFICATIONS
APPLICATIONS
For diesel fuel, marine diesel, light oils, gas oil and
water. Suitable for service stations, diesel fuel skid or storage tanks at
truck stops and marine fuelling stations.
FUEL FLOW RATE: Recommended fuel flow rate of up to 9,600
LPH
WEIGHT:
27.25 kg
SIZE: 135mm (D) x 752 mm (H) x 340 mm (W)
PORT SIZE: 3/4 inch BSPT or NPT threads
OPERATING PRESSURE: 40 psi Maximum
MATERIAL: LM26 marine grade, anti corrosive aluminium
alloy
MAGNETS: Ceramic coated annulus static heterogeneous
magnets
BRACKETS:
Galvanized
mild steel. Mounting holes for 4 x M12 dynabolts (raw plugs)
FLOW DEFLECTORS ¨C Acetyl plastic, resistant to environmental
stress cracking and common solvents including
diesel
SEALS: N70 nit rile rubber, resistant to petroleum, oils alcohols, gasoline,
diester oils and water
Model L9600 Installation & Maintenance Guide - PDF
Go To Next Chapter